PA - 96( S )
PA - 96
Beemet multifunction meter is designed to reduce panel space, wiring and installation time. Its adjustable range reduces inventory. It is used in wide ranging applications such as control panels, distribution systems, gensets, etc.
Salient Features
• Site programmable CT & PT Ratio
• True RMS measurement
• Password protection
• Maximum demand with relay contact
• Optional features:
RS 485 computer interface
60A direct current(Internal CT Module
available)
• Harmonic measurement (total and individual)
• Autoranging
• Universal auxiliary supply
Measuring Parameters
• VL- L (Individual/Average)
• VL- N (Individual/Average)
• Current (Individual/Average)
• Power factor (Individual/Average)
• Frequency
• Power: (Active, Reactive and Apparent)
• Maximum demand: (kW, kVA)
• Peak maximum demand: (kW, kVA)
• Energy (Active, Reactive inductive,
Reactivecapacitive, Apparent)
• Run hour (Import, Export and Total)
• Total Harmonic Distortion “upto 31st” order
ADVANTAGES
• To caution on the Extra Energy Consumption
• To identify inefficiency of Machine/Man
• Reduce Panel Space, Wiring, Installation Time
Measuring Parameters
• Control Panel
• Distribution System
• Generator sets
• Motor Control
• Test Bench
• Energy Management
• Process Control & SCADA
General Specifications
Electrical Connection | 3Ø – 4 wire |
Input Voltage | 0-500 VAC (L-L)/0-300V (L-N) |
Input Current | 0.015A-6A AC |
Frequency | 45 – 65Hz |
Resolution | Energy 0.1 kWh Power factor: 0.001 Frequency: 0.01 Hz Voltage: Autoranging Current: Autoranging Power: Autoranging |
Accuracy | Voltage ±0.5% of F.S. Current ±0.5% of F.S. Power Factor ±0.5% of F.S. Frequency ±0.1% of F.S. Power (Active, Reactive and Apparent): 1% Energy (Active, Reactive and Apparent): Class 1 |
Burden | Voltage: 0.2 VA max. per input Current: 0.2 VA max. per input Auxiliary Supply: 3 VA max. |
Display
Display | 4 rows of 4 digits (For parameter)LED display |
Digit Height | 0.39” (9.9mm) |
Display Scrolling | Automatic/Manual |
Supply Voltage
Auxiliary Supply | 90 – 270V AC/DC (±15%) |
Frequency | 50 / 60Hz |
Output Specifications
Communication | Rs 485 |
Relay Output | 1 C/O relay for max demand |
Environmental Specifications
Temperature | Operating : -10° to 55°C Storage : -20° to 75°C |
Humidity | < 95% RH |
Settable Parameters
C.T Primary | 1/5A to 10000A (Programmable) |
C.T Secondary | 1/5A( Programmable ) |
P.T Ratio | Programmable upto 132 kV |
Display Reset | Energy |
Mechanical Specification
Mounting | Flush Mounting with Side Clamps |
Weight | 280g |
Enclosure Material | ABS Thermoplastic |
Dimensions
Connection Diagram
Ordering Information
Ordering Code | Current Rating | Comm.RS485 |
---|---|---|
PA-96 | 0-5A, CT Programmable | |
PA-96-60A-1P-M | 0-60A, external C for 1 phase (M) | |
PA-96-60A-1P-N | 0-60A, external CT for 1 phase (N) | |
PA-96-60A-1P-NX.X | 0-60A, external CT for 1 phase (NX.X) | |
PA-96-60A-3P-M | 0-60A, external CT for 3 phase (M) | |
PA-96-60A-3P-N | 0-60A, external CT for 3 phase (N) | |
PA-96-60A-3P-NX.X | 0-60A, external CT for 3 phase (NX.X) | |
PA-96-C | 0-5A, CT Programmable | √ |
PA-96-60A-1P-M-C | 0-60A, external CT for 1 phase (M) | √ |
PA-96-60A-1P-N-C | 0-60A, external CT for 1 phase (N) | √ |
PA-96-60A-1P-NX.X-C | 0-60A, external CT for 1 phase (NX.X) | √ |
PA-96-60A-3P-M-C | 0-60A, external CT for 3 phase (M) | √ |
PA-96-60A-3P-N-C | 0-60A, external CT for 3 phase (N) | √ |
PA-96-60A-3P-NX.X-C | 0-60A, external CT for 3 phase (NX.X) | √ |
Accessories | ||
---|---|---|
PA-96 | code | |
for external CT of 60A programmed for single phase | 60A-1P | |
for external CT of 60A programmed for three phase | 60A-3P |
60A-1P
60A-3P
Ordering Code | |
---|---|
The above module to be mounted behind the meter | M |
The above module to be supplied with1 meter long Leads | N |
The above module to be supplied with long leads (any length on request) *Where X.X is length to be specified for eg. 2.5 | NX.X |
FAQ
A power analyzer meter measures electrical power like voltage, current, power in circuits ensuring efficient energy usage and providing help in monitoring performance. It measures these values simultaneously and calculates various electrical characteristics such as active and reactive power. Learn more.
Consider factors such as, measurement accuracy, range, and features like data logging and connectivity while selecting a power analyzer. A digital power analyzer is considered to be ideal for detailed analysis, while simpler models may suffice for basic measurements.
A power analyzer provides real-time measurements of power consumption helping optimize energy usage by providing immediate feedback on power consumption. While an energy meter records total energy used over time identifying areas for improvement, leading to cost savings and efficiency.
Power analyzers are widely used in sectors like manufacturing, building management, and renewable energy monitoring energy efficiency. They are used to reduce operational costs, and ensure optimal performance of electrical systems.
Beemet is a leading company providing power analyzers known for precision, durability, and user-friendly interfaces. We ensure quality and innovation which makes our power analyzers ideal for your requirements.